Acta Orthopaedica Scandinavica · 2000 · 126 citations · 12 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryJoint Replacement SurgeryOrthopedicsRheumatologyKnee ArthroplastyLower Extremity Function AssessmentOutcome AssessmentPatient-reported Outcome MeasuresClinical Measurement ReliabilityFunctional Outcome EvaluationFunctional Outcome MeasurementInter-observer AgreementKnee Function AssessmentObserver Data
We have investigated the reliability of the American Knee Society Score (AKS), a widely used functional outcome score for knee arthroplasty. 29 subjects were assessed in random order by 6 observers, each patient seen twice by each observer. The interobserver reference intervals were 16 points for the Knee Score (0-100 points) and 21 points for the Function Score (0-100 points). The intraobserver reference intervals were smaller, 11 points and 13 points for the Knee Score and the Function Score, respectively. The presence of arthritis in other joints and general debility did not affect the reliability of the scores. The more experienced observers had greater intraobserver reproducibility. Notably, we found moderate agreement between observers in the subjective variables, while the objective variables produced lower levels of agreement. The high inter- and intraobserver variations of the AKS makes estimation of score change questionable. Reliable use of the AKS would necessitate repeated evaluation by an experienced observer.
12
The Measurement of Observer Agreement for Categorical Data
J. Richard Landis, Gary G. Koch · Biometrics · 1977 · 78.9K citations · Full text
Quality of life measures in health care. I: Applications and issues in assessment.
Ray Fitzpatrick, Astrid Fletcher, S M Gore et al. · BMJ · 1992 · 699 citations · Full text
Social Sciences, Health Administration, Health Assessment +16
Reliability of Goniometric Measurements
Donna C. Boone, Stanley P. Azen, Chunmei Lin et al. · Physical Therapy · 1978 · 564 citations