Journal of Applied Physics · 1995 · 39 citations · 13 references
EngineeringPhysicsPlasma PhysicsRadiation DosimetryRadiation MeasurementAbsorbed DoseIon ImplantationRadiation Dose MeasurementFluence Rate DistributionSilicon
A wedge-shaped target was implanted with nitrogen ions using the plasma source ion implantation process, in order to understand the effects of the target edges on the energy and fluence distribution of incident ions. Experimental measurements and analysis of retained dose on silicon samples affixed on the surface of the target, showed results consistent with those predicted by theoretical models. Higher retained dose and greater implantation depths were observed in the vicinity of the edge contained by the normal angle as compared to the edges contained by the acute angles. The target face with smaller area accumulated, on the average, higher dose compared to the face with the larger area.