The Journal of the Acoustical Society of America · 1962 · 13 citations · 0 references
EngineeringElectrical EngineeringProcess ControlPsychoacousticsTime Series AnalysisTemporary Threshold ShiftThreshold ModelingTime-frequency AnalysisCorrection Factor DerivationDuty Cycle CorrectionNoise-induced Temporary Threshold ShiftNoise-induced Threshold ShiftPeriodic Oscillations
The empirical rule that interrupted noise having an on-fraction R produces R times the TTS that the same noise would produce if on continuously (the on-fraction rule) was tested for R≈0.5 and for various duty cycles from 1 min to 16 min. The TTS from the 1-min and 2-min duty cycles agreed with the value predicted by the rule, but the 4-min, 8-min, and 16-min duty cycles gave respectively 1.07, 1.21, and 1.29 times the R-based values. This result indicates that the on-fraction rule breaks down when on-off times exceed about 1 min, but that the rule may be extended for periodic or nearly periodic noises by incorporating correction factor based on the length of the period.