Fiber Optic Sensors for Acoustic Monitoring of PCCP

Mike Higgins, Peter O. Paulson

2006 · 34 citations · 0 references

Concepts

Abstract

Acoustic monitoring of prestressed concrete cylinder pipe (PCCP) has been used on a number of mains through the United States and overseas as an important asset management and/or condition assessment tool. To date, acoustic monitoring has relied on the application of hydrophones or piezoelectric sensors to continuously monitor the acoustic activity in a pipeline to identify the acoustic event associated with a breaking prestressing wire. Hydrophones and piezoelectric sensors have certain limitations that sometimes make it difficult to implement practical monitoring solutions. Recently, a significant advance was made in acoustic monitoring technology for pipelines through the application of fiber optic sensors and optical data acquisition systems. Fiber optic sensors are long continuous glass fiber sensors that are able to transmit light. To manufacture a fiber optic sensor, the glass fiber is run parallel to another fiber that provides strength to resist tension. Both the fiber optic sensor and the strength member are encased in a protective coating to form the fiber optic sensor. The sensor is run through the pipe and one end is attached to an optical data acquisition with a laser that projects a beam of light through the fiber. Acoustic waves in the water column impart pressure waves on the fiber, which in turn, imparts stress waves on the fiber. When the beam of light encounters a changing stress field in the fiber the light is dynamically reflected. This dynamic reflection of light is returned to and analyzed by the data acquisition system to acoustically monitor the pipeline. Since the data acquisition system is using the entire length of fiber as a channel to transmit light, the entire length of fiber is being used as an acoustic sensor. This has many advantages, including the fact that the sensor will, at most, be one pipe diameter away from the acoustic event of interest (i.e., a wire break). This paper will describe the application of acoustic monitoring of PCCP with fiber optic sensors and detail the capabilities and limitations of this monitoring approach. Further, it will describe the application of the fiber optic monitoring system on a 48 in. pipeline where it was run in parallel with an acoustic monitoring system relying on standard hydrophone technology. A comparison of both techniques will be made based on the results of this project.