Radiology · 2007 · 117 citations · 32 references
MedicineHealth InformaticsRadiologyDiagnostic ImagingDiagnostic RadiologyMachine LearningBreast ImagingBreast Lesion CharacterizationCancer DetectionCancer DiagnosisComputer-aided DiagnosisMedical Image AnalysisBenign Breast Disease EvaluationBreast Lesion DiagnosisBreast Mass AssessmentBreast Mass ClassificationCross-validationCross-validation StudiesLinear Discriminant AnalysisNeural Network Modeling
PURPOSE: To retrospectively develop and evaluate computer-aided diagnosis (CAD) models that include both mammographic and sonographic descriptors. MATERIALS AND METHODS: Institutional review board approval was obtained for this HIPAA-compliant study. A waiver of informed consent was obtained. Mammographic and sonographic examinations were performed in 737 patients (age range, 17-87 years), which yielded 803 breast mass lesions (296 malignant, 507 benign). Radiologist-interpreted features from mammograms and sonograms were used as input features for linear discriminant analysis (LDA) and artificial neural network (ANN) models to differentiate benign from malignant lesions. An LDA with all the features was compared with an LDA with only stepwise-selected features. Classification performances were quantified by using receiver operating characteristic (ROC) analysis and were evaluated in a train, validate, and retest scheme. On the retest set, both LDAs were compared with radiologist assessment score of malignancy. RESULTS: Both the LDA and ANN achieved high classification performance with cross validation (area under the ROC curve [A(z)] = 0.92 +/- 0.01 [standard deviation] and (0.90)A(z) = 0.54 +/- 0.08 for LDA, A(z) = 0.92 +/- 0.01 and (0.90)A(z) = 0.55 +/- 0.08 for ANN). Results of both models generalized well to the retest set, with no significant performance differences between the validate and retest sets (P > .1). On the retest set, there were no significant performance differences between LDA with all features and LDA with only the stepwise-selected features (P > .3) and between either LDA and radiologist assessment score (P > .2). CONCLUSION: Results showed that combining mammographic and sonographic descriptors in a CAD model can result in high classification and generalization performance. On the retest set, LDA performance matched radiologist classification performance.
32
Basic principles of ROC analysis
Charles E. Metz · Seminars in Nuclear Medicine · 1978 · 6.1K citations
Solid breast nodules: use of sonography to distinguish between benign and malignant lesions.
A. Thomas Stavros, David Thickman, Cindy Rapp et al. · Radiology · 1995 · 1.8K citations
The positive predictive value of mammography.
Daniel B. Kopans · American Journal of Roentgenology · 1992 · 419 citations
Benign versus Malignant Solid Breast Masses: US Differentiation
Guita Rahbar, Angela Sie, G C Hansen et al. · Radiology · 1999 · 410 citations