Publication | Open Access
Blipped‐controlled aliasing in parallel imaging for simultaneous multislice echo planar imaging with reduced <i>g</i>‐factor penalty
1.3K
Citations
25
References
2011
Year
Image ReconstructionEngineeringAdvanced ImagingParallel ImagingSparse ImagingMagnetic Resonance ImagingComputational ImagingDance ImagesTranslational ImagingRadiation ImagingRadiologyHealth SciencesDiffusion ImagingMedical ImagingNeuroimagingMedical Image ComputingBrain ImagingBiomedical ImagingFunctional X-ray ImagingNeuroscienceInterslice Image Shifts
Simultaneous multislice EPI can shorten acquisition time for diffusion imaging and enable full‑brain high‑resolution fMRI at reduced TR, but unaliasing closely spaced slices is difficult and incurs a high g‑factor penalty. The authors propose a method that introduces interslice image shifts along the phase‑encoding direction to increase the separation between aliasing pixels. The shifts are generated by sign‑ and amplitude‑modulated slice‑select gradient blips applied concurrently with the EPI phase‑encoding blips, and the technique is validated on 3‑ and 7‑T scanners using 32‑channel RF coil arrays. The method achieves the intended shifts without the tilted‑voxel blurring artifact, reduces the average g‑factor penalty to <1 % for 3‑fold slice acceleration (vs 32 % without shifts), yields 19 % (3 T) and 10 % (7 T) penalties when combined with 2‑fold in‑plane acceleration (vs 41 % and 23 % without shifts), and enables a three‑fold faster diffusion acquisition without noticeable degradation in fiber‑orientation uncertainty.
Simultaneous multislice Echo Planar Imaging (EPI) acquisition using parallel imaging can decrease the acquisition time for diffusion imaging and allow full-brain, high-resolution functional MRI (fMRI) acquisitions at a reduced repetition time (TR). However, the unaliasing of simultaneously acquired, closely spaced slices can be difficult, leading to a high g-factor penalty. We introduce a method to create interslice image shifts in the phase encoding direction to increase the distance between aliasing pixels. The shift between the slices is induced using sign- and amplitude-modulated slice-select gradient blips simultaneous with the EPI phase encoding blips. This achieves the desired shifts but avoids an undesired "tilted voxel" blurring artifact associated with previous methods. We validate the method in 3× slice-accelerated spin-echo and gradient-echo EPI at 3 T and 7 T using 32-channel radio frequency (RF) coil brain arrays. The Monte-Carlo simulated average g-factor penalty of the 3-fold slice-accelerated acquisition with interslice shifts is <1% at 3 T (compared with 32% without slice shift). Combining 3× slice acceleration with 2× inplane acceleration, the g-factor penalty becomes 19% at 3 T and 10% at 7 T (compared with 41% and 23% without slice shift). We demonstrate the potential of the method for accelerating diffusion imaging by comparing the fiber orientation uncertainty, where the 3-fold faster acquisition showed no noticeable degradation.
| Year | Citations | |
|---|---|---|
Page 1
Page 1