Journal of Vacuum Science & Technology B Microelectronics Processing and Phenomena · 1988 · 15 citations · 0 references
Life SciencesCell BiologyCell EngineeringGene RegulationSingle-cell Systems BiologyCell Culture MicrosystemsShutter SpeedExperimental Results InterpretationFeedback Control TheoryManual Control DesignManual Temperature ControlMolecular Beam EpitaxyMolecular Beam Epitaxy KineticsSet Point Regulation
We present an analysis, based on control theory, of the transients in flux from a molecular-beam epitaxy source cell which occur after opening the shutter and also after changing the set point of the cell temperature controller. This analysis permits the calculation of the variation of this set point with time which produces a transient equal and opposite to that following shutter operation. Experimental results show that use of this set point variation results in a beam flux constant to within 1%, and that the parameters in this analysis do not change significantly over at least 100 h of cell operation. In addition we show that simple manual control of the set point based on this analysis can reduce the flux transient by a factor of 5.