Canadian Journal of Civil Engineering · 2005 · 12 citations · 6 references
EngineeringCivil EngineeringBridge EngineeringStructural AnalysisStructural EngineeringBridge DesignBridge StrengtheningSteel StructuresStructural MechanicsStructural Performance AnalysisTruss BridgesDeflection Behavior Of Truss BridgesElastic ModulusSteel Truss BridgesSteel Truss StructuresStrengtheningStrengthening Of Truss BridgesTruss RedundancyTruss Strengthening
The post-tensioning method has been successfully used to improve the performance of existing concrete structures. Applications of the method are rare in steel structures, however. Post-tensioning using high-strength cables or bars can be effectively used to increase the working load carrying capacity of steel structures. In this paper, the elastic behavior of post-tensioned trusses with straight and draped tendon profiles for truss strengthening is examined. The effects of design parameters such as the tendon profile, truss type, prestressing force, and tendon eccentricity on working load and deflection of trusses are studied. The results show that the allowable load of a truss increases proportionally with the increase in prestressing force and eccentricity. Post-tensioning enlarges the elastic range, increases the redundancy, and reduces the deflection and member stresses, eventually increasing the load-carrying capacity of truss bridges.Key words: post-tensioning method, steel structures, post-tensioned trusses, truss strengthening, design parameters, load-carrying capacity.
6