Instrumental modifications for compressive testing under hydrostatic confining conditions

P. Veyssière, J. Rabier, M. Jaulin, J. L. Démenet, J. Castaing

Revue de Physique Appliquée · 1985 · 26 citations · 6 references

DOIFull text

Open access

Concepts

Abstract

The device originally designed by D. T. Griggs [1] in order to deform minerals in compression under a confining pressure has been modified and adapted to the study of the plasticity of metal alloys and semi-conductors. The changes take advantage of a commercial testing machine, they also ensure an improved rigidity of the machine. In addition, friction has been reduced to such a level that the minimum flow stress which is now detectable has dropped by one order of magnitude. In complement, a servocontrolled microleak permits an adjustable low depressurization of the confining medium and eliminates the destruction of the samples by fracture which occurs usually at the end of a standard test.

References

6