Plasma Medicine · 2011 · 14 citations · 33 references
EngineeringEnvironmental EngineeringMicrobiologyWastewater TreatmentWater Quality EngineeringWater TreatmentEnvironmental DisinfectionWastewater MicrobiologyWater Quality MicrobiologyEscherichia ColiHydrogen Peroxide GenerationLog Reduction ValueLow Ph InactivationOxidizing DisinfectantsPlasma TreatmentWater Disinfection SystemsWater Injection
The efficacy of gliding arc (GA) discharge for the generation of hydrogen peroxide (H 2 O 2 ) and water with a low pH was studied because H 2 O 2 combined with low-pH environment is known as a strong oxidizer that can be used for the bacterial inactivation. The ability of the GA discharge to inactivate Escherichia coli in water was tested experimentally, and the inactivation was found to increase with the plasma treatment time and rate of water injection flow to the GA discharge system. The best result showed a 2-log reduction of the number of colony-forming units of E. coli from 10 4 to 10 2 at a water injection flow rate of 180 mL/min. Furthermore, pH in the plasma-treated water was decreased from 6.0 to 3.55 after 25 min of treatment.
33
Physical and biological mechanisms of direct plasma interaction with living tissue
Danil Dobrynin, Gregory Fridman, Gary Friedman et al. · New Journal of Physics · 2009 · 782 citations · Full text