2012 · 46 citations · 9 references
EngineeringElectrical EngineeringCircuit TheoryElectromagneticsElectromagnetismElectric CircuitsKirchhoff's LawsMagnetic Circuit AnalysisMagnetic ComponentsCircuit SimulationElectromagnetic Transient SimulationEquivalent CircuitsHysteresisMagnetic Core MaterialsMagnetic Equivalent CircuitsMagnetic FluxTransient Electromagnetic Simulation
When modeling magnetic components, the permeance-capacitance analogy avoids the drawbacks of traditional equivalent circuits models. The magnetic circuit structure is easily derived from the core geometry, and the energy relationship between electrical and magnetic domain is preserved. Non-linear core materials can be modeled with variable permeances, enabling the implementation of arbitrary saturation and hysteresis functions. Frequency-dependent losses can be realized with resistors in the magnetic circuit. The magnetic domain has been implemented in the simulation software PLECS. To avoid numerical integration errors, Kirchhoff's current law must be applied to both the magnetic flux and the flux-rate when solving the circuit equations.
9
Theory of ferromagnetic hysteresis
David Jiles, D.L. Atherton · Journal of Magnetism and Magnetic Materials · 1986 · 2.2K citations
Theory of ferromagnetic hysteresis (invited)
David Jiles, D.L. Atherton · Journal of Applied Physics · 1984 · 672 citations
David Jiles, D.L. Atherton · IEEE Transactions on Magnetics · 1983 · 416 citations
Natural Sciences, Materials Science, Computational Materials Science +14