Perfusion · 1997 · 19 citations · 14 references
MedicineCardiologySurgeryCardiothoracic SurgeryEnhanced Recovery After SurgeryHemodynamic ManagementCardiopulmonary BypassComplement RegulationComplement SystemExtracorporeal CirculationExtracorporeal Life SupportExtracorporeal Membrane OxygenationComplement Activation AssaysFlat Sheet MembranesImmune Cell Activation MarkersInflammatory ActivationMembrane Oxygenator TechnologyPolypropyleneProtamine AdministrationProtamine Sulfate
The inflammatory reaction of extracorporeal circuits can be assessed by measuring complement activation and the release of activation markers of leucocytes. The purpose of this study was to compare three commercially available membrane oxygenators with respect to complement (C3a), granulocyte (lactoferrin) and monocyte (interleukin-6, IL-6) activation. Thirty patients undergoing cardiac surgery were randomly assigned to undergo cardiopulmonary bypass (CPB) with one of the following oxygenators: a polypropylene hollow-fibre membrane (group 1; 2.2 m2), a polypropylene flat-sheet membrane (group 2; 3.1 m2) or a silicone envelope membrane (group 3, 3.5 m2). In all patients, a significant increase in C3a in plasma occurred during CPB with peak levels after the administration of protamine sulphate. In blood samples taken before aortic crossclamp release, at the end of CPB, and 20 min after protamine administration C3a was significantly lower in group 1 than in the other two groups. Lactoferrin increased significantly during CPB in all patients without a significant difference between the groups. IL-6 did not increase during CPB, but raised significantly after 4 h in the intensive care unit in all groups. Moreover, IL-6 was significant lower in group 1 than group 3. The data suggest that the polypropylene hollow-fibre membrane oxygenator, i.e. the oxygenator with the smallest surface area, is more biocompatible than the other types, probably because of a smaller contact surface area.
14
Complement and the damaging effects of cardiopulmonary bypass
James K. Kirklin, James K. Kirklin, Stephen Westaby et al. · Journal of Thoracic and Cardiovascular Surgery · 1983 · 1.3K citations
Medicine, Cardiology, Surgery +12
Complement Activation during Cardiopulmonary Bypass
Dennis E. Chenoweth, Steven W. Cooper, Tony E. Hugli et al. · New England Journal of Medicine · 1981 · 1.2K citations
Medicine, Immunology, Surgery +12
Sensitive ELISA for interleukin-6
Maarten Helle, L C Boeije, Els de Groot et al. · Journal of Immunological Methods · 1991 · 250 citations
Complement activation during cardiopulmonary bypass
Nicholas C. Cavarocchi, James R. Pluth, Hartzell V. Schaff et al. · Journal of Thoracic and Cardiovascular Surgery · 1986 · 180 citations
Medicine, Immunology, Surgery +12