Journal of Dairy Science · 1962 · 14 citations · 1 references
AgricultureAnimal SciencesDairy ScienceLactationLactation PhysiologyMilk QualityMilk HygieneMilking ManagementUdder HealthMilking Vacuum RegulationSensory DeteriorationUdder ExaminationUdder Health AssessmentUdder Health WelfareUdder HygieneVacuum Pressure Settings
A floor-type milking machine was altered by substitution of a motor-driven nylon petcock for the conventional one. I n this way, the level of vacuum in the teat cups was made to vary between 7 and 15 in. of mercury at a rate of 53 vacuum fluctuations per minute. Two trials, each utilizing 12 cows, were conducted. The test periods were of 21 and 26 days' duration, and each followed preliminary standardization periods. In each trial, two cases of clinical mastitis developed among the six cows milked with the altered machine. California Mastitis Test scores on milk produced by the experimental cows rose significantly, as compared with scores on milk front control animals. Direct leucocyte count of the milk also increased, due mainly to the mastitic cows. Hotis tests, on milks produced in Trial II, indicated little change in reactions, other than ~ marked increase in alkalinity of the milk from experimental cows. There was little difference in amounts of milk produced by control and experimental animals. A longer time was required to milk with the variable vacuum machine.