Journal of Environmental Quality · 1989 · 81 citations · 0 references
EngineeringDairy ScienceEnvironmental EngineeringWaste ManagementWastewater TreatmentWater TreatmentNutrient Recovery From Dairy WasteNutrient RemovalNutrient RetentionNutrient RunoffWaste TreatmentWastewater CharacterizationConcentrationNutrient Retention PerformanceNutrient Runoff MitigationPhosphorus Removal EfficiencySurface Runoff ProcessesVegetated Filter Strip PerformanceVegetated Filter StripsVegetative Filter Strips
Abstract A vegetated filter strip constructed to treat milkhouse wastewater from a Vermont dairy farm was evaluated to determine its effectiveness in reducing solids, P and N concentrations and exports in surface and subsurface flow. The liquid waste was applied twice daily via a level lip spreader at a rate of 2.94 cm/wk on a vegetated loam soil having a 2% slope. The flow and concentrations of inputs and surface and subsurface outputs were continuously monitored during the 2‐yr study. The strip significantly ( P < 0.01) reduced solids, P, and N on a concentration basis, and retained 95% solids, 89% P, and 92% N on a mass basis. Retention was the greatest during the growing season and the poorest during snowmelt periods. Concentrations in subsurface outputs were greater than in surface runoff and over 75% of the mass export was in subsurface flow. Comparisons of this study with values reported in the literature suggests that hydraulic loading rate governs the effectiveness of filter strip treatment.