Far-ir heterodyne radiometric measurements with quasioptical Schottky diode mixers

H. R. Fetterman, P. E. Tannenwald, B. J. Clifton, C. D. Parker, W. D. Fitzgerald, N. R. Erickson

Applied Physics Letters · 1978 · 139 citations · 5 references

Concepts

Abstract

We have made heterodyne radiometric measurements with GaAs Schottky diode mixers, mounted in a corner-reflector configuration, over the spectral range 170 μm to 1 mm. At 400 μm, system noise temperatures of 9700 K DSB (NEP=1.4×10−19 W/Hz) and mixer noise temperatures of 5900 K have been achieved. This same quasioptical mixer has also been used to generate 10−7 W of tunable radiation suitable for spectroscopic applications.

References

5