Concepedia

Publication | Closed Access

Airflow and temperature distribution inside the maxillary sinus: A computational fluid dynamics simulation

20

Citations

9

References

2012

Year

Abstract

The airflow velocity in maxillary sinuses (average velocity 0.062 m/s) was much lower than that in the middle meatus (average velocity 3.26 m/s). With the increase of ostium diameter, airflow characteristics distributed in the maxillary sinuses changed little. The normal temperature in the maxillary sinus remained almost constant at 34°C and changed little with the increase of ostium diameter.

References

YearCitations

Page 1