DentistryDental Materials ScienceDental MaterialsDigital ProsthodonticsProsthodontic MaterialsAll-ceramic RestorationsCrown MaterialsCad And Cam Crown MaterialsCad And Cam Dental CeramicsCeramic Crown SystemsComputer-aided Crown FabricationComputer-aided Design (Cad And Cam) CrownsCrown Width MeasurementMarginal Gap AnalysisPorcelain Crowns
The purpose of this study was to evaluate the marginal and internal fit of all-ceramic crowns fabricated using the Decsy CAD/CAM system. A master die of maxillary first premolar was measured, and experimental crowns were fabricated. Four conditions were established by combining two convergence angles (4 degrees and 12 degrees) of the abutment with two different luting space settings (15 microm and 55 microm). The results showed that the experimental crowns had a marginal gap of 42 to 56 microm. When the luting space setting was 15 microm, the internal gap was 85-88 microm; when the setting was 55 microm, the internal gap was 126-138 microm. The marginal gap for each experimental crown met the clinically acceptable criterion.
21
The estimation of cement film thickness by an in vivo technique
J W McLean, Fraunhofer von · BDJ · 1971 · 1.4K citations
A comparison of the marginal fit of In-Ceram, IPS Empress, and Procera crowns.
Frankie Sulaiman, John Chai, Lee M. Jameson et al. · PubMed · 1998 · 328 citations
Marginal and internal fit of Cerec 3 CAD/CAM all-ceramic crowns.
Takashi Nakamura, Nobuyoshi Dei, Tetsuya Kojima et al. · PubMed · 2003 · 233 citations