Evaluation of the overall efficacy of the Omron office digital blood pressure HEM-907 monitor in adults

William B. White, Yusra Anis Anwar

Blood Pressure Monitoring · 2001 · 213 citations · 7 references

Concepts

TL;DR

Non‑invasive self‑blood‑pressure monitoring is increasingly popular, but devices must be independently validated before marketing. This study aimed to evaluate the accuracy of the Omron HEM‑907, a semi‑automatic oscillometric monitor intended for clinic use. Blood‑pressure readings from 100 subjects (384 measurements) were compared to mercury sphygmomanometer measurements by two observers, and limits of agreement were calculated per AAMI standards. The HEM‑907 met AAMI accuracy criteria, with device–observer agreement of 1.56 ± 4.42 mmHg systolic and 3.49 ± 4.61 mmHg diastolic, while observer–observer agreement was –0.36 ± 2.32 mmHg systolic and 0.02 ± 2.42 mmHg diastolic.

Abstract

Background Non-invasive self blood pressure monitoring has become increasingly popular. To assure the accuracy of devices used for this purpose, all need to be validated independently prior to marketing. The objective of this study was to assess the accuracy of the HEM-907, a new semi-automatic, non-invasive, oscillometric blood pressure monitoring device specifically designed to be used in the clinic or physician's office setting. Methods Blood pressure measurements taken employing this device were compared with the results obtained by two experienced observers using a mercury sphygmomanometer on 100 subjects and patients (384 measurements). The limits of agreement were calculated for the device compared with the results of the two observers according to the standards of the Association for the Advancement of Medical Instrumentation (AAMI). Results The agreement between the two observers was –0.36 ± 2.32 mmHg for systolic blood pressure and 0.02 ± 2.42 mmHg for diastolic blood pressure. The agreement between the device and the observers was 1.56 ± 4.42 mmHg and 3.49 ± 4.61 mmHg for systolic and diastolic blood pressure respectively. Conclusions The Omron HEM-907 satisfied the AAMI criteria for accuracy for a non-invasive blood pressure monitoring device.

References

7