NeuroImage · 2011 · 583 citations · 62 references
EngineeringNeuroscienceNeural EngineeringNeurophysiologySensor FusionBrain ImagingBrain-computer InterfacesElectroencephalogram AnalysisElectroencephalogram Signal ProcessingElectroencephalographyNear-infrared SpectroscopyAccuracyBrain-computer Interface Performance EvaluationClassification AccuracyClassification Accuracy AnalysisClassification Accuracy AssessmentElectroencephalography-based Brain-computer InterfacesMotor Imagery ClassificationMotor Imagery Decoding
Noninvasive BCIs are promoted for neuroprosthetics, yet EEG‑based applications reveal a need for improved accuracy and stability. The study investigates whether adding NIRS can enhance EEG‑based BCI by complementing real‑time classification. Both NIRS and EEG were recorded simultaneously during a real‑time SMR‑based BCI involving executed movements and motor imagery, and NIRS classification was tested for complementing EEG. Simultaneous NIRS–EEG improved motor‑imagery classification accuracy in over 90 % of subjects, raising performance by 5 % on average, though the hemodynamic delay may limit bit‑rate gains; the complementary information content confirms the viability of this multimodal BCI.
Noninvasive Brain Computer Interfaces (BCI) have been promoted to be used for neuroprosthetics. However, reports on applications with electroencephalography (EEG) show a demand for a better accuracy and stability. Here we investigate whether near-infrared spectroscopy (NIRS) can be used to enhance the EEG approach. In our study both methods were applied simultaneously in a real-time Sensory Motor Rhythm (SMR)-based BCI paradigm, involving executed movements as well as motor imagery. We tested how the classification of NIRS data can complement ongoing real-time EEG classification. Our results show that simultaneous measurements of NIRS and EEG can significantly improve the classification accuracy of motor imagery in over 90% of considered subjects and increases performance by 5% on average (p<0:01). However, the long time delay of the hemodynamic response may hinder an overall increase of bit-rates. Furthermore we find that EEG and NIRS complement each other in terms of information content and are thus a viable multimodal imaging technique, suitable for BCI.
62
Information theory, inference, and learning algorithms
Choice Reviews Online · 2004 · 6.6K citations
Neurophysiological investigation of the basis of the fMRI signal
Nikos K. Logothetis, J Pauls, M Augath et al. · Nature · 2001 · 6.5K citations
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Benjamin Blankertz, Ryota Tomioka, Steven Lemm et al. · IEEE Signal Processing Magazine · 2008 · 2.1K citations