MedicineBioengineeringBiomedical EngineeringBiomedical Signal ProcessingMotor ControlProstheticsElectromyogram AnalysisMuscle Signal ProcessingMyoelectric ProsthesesProsthetic Control SystemsProsthetic RehabilitationUpper-limb ProstheticsElectromyographyElectromyography Signal ClassificationElectromyography-based Prosthetic ControlLong-term StabilityMuscles Of The ForearmProsthetic Control Using ElectromyographySurface ElectromyographyUpper-limb Prosthesis Control
Long-term functioning of a hand prosthesis is crucial for its acceptance by patients with upper limb deficit. In this study the reliability over days of the performance of pattern classification approaches based on surface electromyography (sEMG) signal for the control of upper limb prostheses was investigated. Recordings of sEMG from the forearm muscles were obtained across five consecutive days from five healthy subjects. It was demonstrated that the classification performance decreased monotonically on average by 4.1% per day. It was also found that the accumulated error was confined to three of the eight movement classes investigated. This contribution gives insight on the long term behavior of pattern classification, which is crucial for commercial viability.