EngineeringBioengineeringBiomedical EngineeringBioinstrumentationBiomedical Signal ProcessingProstheticsElectrode PlacementElectromyogram AnalysisMuscle Signal ProcessingMyoelectric ProsthesesProsthetic Control SystemsProsthetic DevicesClassification AccuracyClassification Accuracy AnalysisClassification SensitivityControl System RobustnessElectrode MisplacementElectromyographyMyoelectric ControlMyoelectric Prosthesis Control
Myoelectric pattern recognition systems for prosthesis control face clinical viability challenges, notably maintaining usability amid socket misalignment that causes electrode contact shifts during donning and doffing. The study examined how electrode detection surface size and pole placement influence system robustness to electrode shift. We evaluated the impact of electrode size and orientation on pattern recognition robustness by testing different electrode configurations under shift and no‑shift conditions. Electrodes aligned parallel to muscle fibers outperformed perpendicular ones, with perpendicular shifts causing greater accuracy loss; larger electrodes mitigated sensitivity to perpendicular shifts but did not improve controllability, whereas a combination of longitudinal and transverse electrodes maintained high controllability both with and without shift using only four pole locations.
Myoelectric pattern recognition systems for prosthesis control are often studied in controlled laboratory settings, but obstacles remain to be addressed before they are clinically viable. One important obstacle is the difficulty of maintaining system usability with socket misalignment. Misalignment inevitably occurs during prosthesis donning and doffing, producing a shift in electrode contact locations. We investigated how the size of the electrode detection surface and the placement of electrode poles (electrode orientation) affected system robustness with electrode shift. Electrodes oriented parallel to muscle fibers outperformed electrodes oriented perpendicular to muscle fibers in both shift and no-shift conditions (p <; 0.01). Another finding was the significant difference (p <; 0.01) in performance for the direction of electrode shift. Shifts perpendicular to the muscle fibers reduced classification accuracy and real-time controllability much more than shifts parallel to the muscle fibers. Increasing the size of the electrode detection surface was found to help reduce classification accuracy sensitivity to electrode shifts in a direction perpendicular to the muscle fibers but did not improve the real-time controllability of the pattern recognition system. One clinically important result was that a combination of longitudinal and transverse electrodes yielded high controllability with and without electrode shift using only four physical electrode pole locations.
29
Muscles Alive—their functions revealed by electromyography
Postgraduate Medical Journal · 1963 · 1.8K citations · Full text