Catheterization and Cardiovascular Interventions · 2005 · 35 citations · 26 references
MedicineCardiologySurgeryCardiothoracic SurgeryClinical CardiologyInterventional CardiologyBalloon AngioplastyCoronary AngioplastyCoronary Artery DiseaseCoronary Artery SurgeryIschemic Heart DiseasePercutaneous Coronary InterventionBalloon-expandable StentsComplications Of Stent PlacementCoronary Stent RestenosisCoronary StentingIn-stent ThrombosisRestenosis After StentingSlippage
The occurrence of balloon slippage ("watermelon seeding"; WMS) during treatment of patients with in-stent restenosis (ISR) has been described, but predisposing factors and the potential implications of this phenomenon remain unknown. In the Restenosis Intrastent: Balloon Angioplasty vs. Elective Stenting (RIBS) randomized study, 450 patients with ISR were included. Of these, 42 patients (9%) presented WMS during the procedure. WMS was detected in 26 patients (12%) in the balloon arm and 16 (7%) in the stent arm (P=0.11). In the stent arm, WMS was only noticed during balloon predilation, never during stent implantation. As compared with 408 patients without WMS, patients with WMS had more severe (TIMI flow 1; 21% vs. 8%; P=0.01) and diffuse (length>15 mm: 45% vs. 28%; P=0.02) ISR lesions. Patients with WMS required more balloon inflations, longer total inflation time, had more frequent crossover to stenting or ended the procedure with residual dissections, and eventually obtained poorer acute results (minimal lumen diameter, 2.35+/-0.5 vs. 2.53+/-0.5 mm; P=0.03). In addition, at 6-month follow-up, patients with WMS had a smaller minimal lumen diameter (1.26+/-0.7 vs. 1.61+/-0.7 mm; P=0.007) and a higher restenosis rate (56% vs. 37%; P=0.017). On logistic regression analysis, the WMS phenomenon emerged as an independent predictor of recurrent restenosis (adjusted RR=2.1; 95% CI=1.1-4.1; P=0.04). The WMS phenomenon may complicate treatment of patients with ISR. Long and severe lesions appear to predispose to this technical problem that never occurs during stent deployment. In patients with ISR, WMS is associated with cumbersome procedures and poorer acute and long-term angiographic results.
26
Patrick W. Serruys, Peter de Jaegere, Ferdinand Kiemeneij et al. · New England Journal of Medicine · 1994 · 4.5K citations · Full text
Angiographic Patterns of In-Stent Restenosis
Roxana Mehran, George Dangas, Gary S. Mintz et al. · Circulation · 1999 · 1.3K citations
Patterns and Mechanisms of In-Stent Restenosis
Rainer Hoffmann, Gary S. Mintz, G Dussaillant et al. · Circulation · 1996 · 1.3K citations
Catheter-Based Radiotherapy to Inhibit Restenosis after Coronary Stenting
Paul S. Teirstein, Vincent Massullo, Shirish Jani et al. · New England Journal of Medicine · 1997 · 943 citations
Medicine, Cardiology, Surgery +14
Arterial Remodeling After Coronary Angioplasty
Gary S. Mintz, Jeffrey J. Popma, Augusto D. Pichard et al. · Circulation · 1996 · 888 citations
Medicine, Cardiology, Surgery +17