Plasma Physics · 1978 · 14 citations · 3 references
Natural SciencesNuclear EngineeringPhysicsElectromagnetismNuclear PhysicsPlasma PhysicsFusion PlasmasHigh-temperature PlasmasMagnetic Confinement FusionMagnetized PlasmaNuclear FusionPlasma ConfinementBreakdown PressureBreakdown VoltagePlasma BreakdownTokamak ConfinementTokamak PhysicsTokamak PlasmasToroidal ConfinementToroidal Magnetic Fields
The breakdown condition of hydrogen gas in the JFT-2 apparatus is investigated by changing externally applied vertical and horizontal fields, and by performing the experiment with the plasma current either parallel or antiparallel to the toroidal magnetic field. There is an optimum value of the external field which gives the most favourable breakdown. The breakdown voltage-pressure curve shows the effect of the toroidal drift due to the curvature and the gradient of the strength of the toroidal field on breakdown. The separate effect of the vertical field due to the toroidal field coil system or to the liner current is made clear by examining the experimental results.
3
Absolute Values of the Electron Mobility in Hydrogen
Norris E. Bradbury, Russell A. Nielsen · Physical Review · 1936 · 339 citations
The ontogeny of a Tokamak discharge
D. Dimock, H.P. Eubank, E. Hinnov et al. · Nuclear Fusion · 1973 · 87 citations