Optica Acta International Journal of Optics · 1983 · 12 citations · 9 references
EngineeringPhysicsMetrologyOpticsPhotonicsDoppler Velocity MeasurementFlow MeasurementFlow MetrologyLaser OpticsOptical InstrumentationOptical MetrologyBlood Flow MeasurementDiscrete Fourier TransformFourier TransformLaser Doppler MetrologyLaser Doppler VelocimetryPhoton Correlation FunctionsVelocity
Cross-beam laser velocimetry using Bragg shift and photon correlation has been utilized to measure a weak secondary flow component in the presence of strong primary flow at right angles to it. To obtain this velocity component with adequate accuracy, the apparent Doppler frequency was determined by Fourier transformation of the correlogram followed by two steps of interpolating correction. The remaining frequency error may be as little as 10-2 j f where integral multiples of j f are the abscissa values for which the discrete Fourier transform is given. Finally a method is described which allows precise orientation of the cross-beam fringes at right angles to the secondary flow component; it makes use of symmetry properties of the flow in question.
9
Principles and Practice of Laser-Doppler Anemometry
F. Durst, A. Melling, J. H. Whitelaw et al. · Journal of Applied Mechanics · 1977 · 1K citations · Full text
Principles and practice of laser-Doppler anemometry
J. B. Abbiss · Optics & Laser Technology · 1976 · 317 citations
Harry L. Swinney, J. P. Gollub · Physics Today · 1978 · 178 citations