Thrombosis and Haemostasis · 2010 · 59 citations · 24 references
MedicineHematologyImmunologyClinical ImmunologyEarly DetectionMolecular DiagnosticsAnticoagulant TherapyAnticoagulation TherapyAntigen Detection AssaysEnzyme-linked Immunosorbent AssayImmunoassay AnalysisImmunoassay DevelopmentChemiluminescent BiosensorsFalse Negative DetectionHeparin AnticoagulationHigh-sensitivity AssaysImmunoassay MethodologyMonitoring Of Anticoagulant TherapyPlatelet Activation AssaysThrombotic Complication Monitoring
Heparin-induced thrombocytopenia (HIT) is a life-threatening complication of heparin treatment; the prognosis depends on early and accurate diagnosis, and prompt start of alternative anticoagulants. Because of high sensitivity, the commercially available immunologic assays are widely used, though not suited to be run on single samples and with a turnaround time of 2-3 hours. We evaluated two new, rapid, automated, semi-quantitative chemiluminescent immunoassays in HIT suspected patients: HemosIL AcuStar HIT-IgG(PF4-H) (specific for IgG anti-PF4/heparin antibodies) and HemosIL AcuStar HIT-Ab(PF4-H) (detecting IgG, IgM and IgA anti-PF4/heparin antibodies) (both from Instrumentation Laboratory). A total of 102 patients with suspected HIT were included; HIT was diagnosed in 17 (16.7%). No false negative cases were observed using either the HemosIL AcuStar HIT-IgG(PF4-H) or the HIT-Ab(PF4-H) assay (sensitivity and negative predictive values = 100%; negative likelihood ratios <0.01). The specificity was higher for the HemosIL AcuStar HIT-IgG(PF4-H) in comparison with that of the HemosIL AcuStar HIT-Ab(PF4-H) (96.5% vs. 81.2%). Higher values of the HemosIL AcuStar HIT-IgG(PF4-H) were associated with increased probability of HIT. Patients with confirmed HIT and thrombotic complications had significantly higher levels of HemosIL AcuStar HIT-IgG(PF4-H) than those without thrombotic complications. The HemosIL AcuStar HIT-IgG(PF4-H) and HIT-Ab(PF4-H) assays showed a very high sensitivity, and therefore they can reliably be used to rule out HIT in suspected patients. The diagnostic specificity was greatly increased by using the HemosIL AcuStar HIT-IgG(PF4-H). Both the assays are reproducible (CVs <6%), rapid (turnaround time 30 minutes), automated, and semi-quantitative, and they can be run for single sample testing.
24
Refining clinical diagnosis with likelihood ratios
David A. Grimes, Kenneth F. Schulz · The Lancet · 2005 · 828 citations
Argatroban Anticoagulant Therapy in Patients With Heparin-Induced Thrombocytopenia
Bruce Lewis, Diane E. Wallis, Scott D. Berkowitz et al. · Circulation · 2001 · 664 citations · Full text
Medicine, Hematology, Pharmacology +17
TE Warkentin, L Boshkov, AV Santos et al. · Blood · 1994 · 486 citations · Full text
Medicine, Hematology, Immunology +16
A Rapid and Sensitive Test for Diagnosing Heparin-Associated Thrombocytopenia
Andreas Greinacher, I. Michels, V. Kiefel et al. · Thrombosis and Haemostasis · 1991 · 386 citations
Medicine, Hematology, Pharmacology +17