Applied Optics · 1969 · 136 citations · 21 references
EngineeringElectrical EngineeringPhysicsOpticsOptoelectronicsPhotonicsDetector EfficiencyDetector TechnologyElectron CountingPhotodetectorsPhotoelectron SpectroscopyQuantum OptoelectronicsCounting EfficiencyDark CurrentDetector Quantum EfficiencyPhotomultiplier DetectorsPhotomultiplier TubesPhoton CountingPhoton-counting DetectorsQuantum Efficiency
A number of photomultiplier tubes have been assessed for application in experiments where the counting of individual photoelectrons from the photocathode is necessary or advantageous. Pulse height distributions, signal-to-noise-in-signal ratios, over-all quantum-counting efficiencies, time dependent statistical correlations, and dark current properties have been investigated and compared with theoretical expectations. Amajor finding has been the general low value of over-all quantum-counting efficiency. Direct measurements of this figure have not, to our knowledge, been published previously. A second conclusion has been that, although there seems to be no reason why high performance with respect to each of the features considered should not be achieved in a single tube, we have not yet found one in which this is so.
21
Statistics of Electron Multiplication
Francis J. Lombard, F. A. Martin · Review of Scientific Instruments · 1961 · 124 citations
G. A. Morton · Applied Optics · 1968 · 114 citations
Dead-Time Corrections to Photon Counting Distributions
F. A. Johnson, R. Jones, Thomas McLean et al. · Physical Review Letters · 1966 · 84 citations
Statistics of the laser radiation at threshold
F. T. Arecchi, G.S. Rodari, A. Sona · Physics Letters A · 1967 · 76 citations
Natural Sciences, Biophysics, Optics +11