Analytical Chemistry · 2009 · 85 citations · 33 references
Natural SciencesElectrical EngineeringMaterials ScienceElectrochemistryInstrumentationSurface ScienceCurrent DistributionElectrical CharacterizationElectrode-electrolyte InterfacesReference ElectrodesScanning Probe MicroscopySurface PhysicsConductance Measurement TechniquesCurrent Flow ModelingCurrent-potential RelationshipsFeedbackIon ConductanceScanning Electrochemical MicroscopyTip - Sample InteractionsTip-sample Interactions
Scanning ion conductance microscopy (SICM) is a scanned probe microscopy technique in which the probe is a fine glass pipet filled with a contact (reference) electrode and an electrolyte solution. The current flow between the reference electrode and a second reference electrode positioned in bulk solution when the two electrodes are biased externally can be used as a feedback signal to maintain a constant separation between the tip and a surface during imaging. In usual practice the tip position is modulated over a small amplitude perpendicular to the surface, and the resulting alternating current (AC) is used as the feedback signal, although the direct current can also be used. A comprehensive model for the current response is reported. Laplace's equation has been solved for the electrolyte solution for a range of tip geometries, enabling the factors controlling the tip current to be identified. The approach developed is shown to represent an improvement over earlier semiempirical treatments. To explore the influence of surface topography on the (AC) current response, various surfaces have been considered, including a tip moved toward a planar surface (in the normal direction) and tips scanned over a pit and a step in the surface. The results have allowed a critical assessment of the SICM response as a means of probing surface topography. Features identified through simulation have been found in experiments through studies of two model substrates for which imaging results are reported. In typical experimental practice, the response of the SICM tip to surface features occurs over much greater lateral distances than the size of the pipet aperture.
33
Scanning electrochemical microscopy. Introduction and principles
Allen J. Bard, Fu Ren F. Fan, Juhyoun Kwak et al. · Analytical Chemistry · 1989 · 1.1K citations
The Scanning Ion-Conductance Microscope
Paul K. Hansma, B. Drake, Othmar Marti et al. · Science · 1989 · 846 citations
Resistance for Flow of Current to a Disk
John Newman · Journal of The Electrochemical Society · 1966 · 716 citations · Full text
Ivan Vlassiouk, Zuzanna S. Siwy · Nano Letters · 2007 · 622 citations
Natural Sciences, Electrical Engineering, Materials Science +12