Magnetic Resonance in Medicine · 1991 · 124 citations · 8 references
MedicineNeurobiologyNeuroscienceBiomedical ImagingDiagnostic ImagingNeurophysiologyBrain ImagingCerebral Blood FlowCerebral PhysiologyMagnetic Resonance ImagingMagnetic Resonance SpectroscopyPerfusion ImagingBlood FlowCerebral Blood Flow QuantificationConcentrationDirect Oxygen Consumption MeasurementMagnetic Resonance Flow QuantificationOxygen Delivery To Brain
We used 17O NMR imaging techniques to measure the H2(17)O concentration in a 0.8-ml voxel in the cat brain following injection of an arterial bolus of enriched H2(17)O and during inhalation of enriched 17O2. We also measured the H2(17)O concentration in arterial blood during 17O2 inhalation. The data from the first measurement were used to calculate the blood flow in the voxel. The data from all three measurements were combined to calculate the oxygen consumption in the voxel. The values of cerebral blood flow and oxygen consumption calculated with 17O NMR techniques agree reasonably well with values calculated for a similar region of the cat brain using autoradiographic techniques.
8
Mapping of metabolites in whole animals by 31P NMR using surface coils
Joseph J. H. Ackerman, Thomas H. Grove, Gordon Wong et al. · Nature · 1980 · 1K citations
Frank A. Welsh, Harvey M. Shapiro · Anesthesiology · 1979 · 647 citations