MedicineCardiologyPhysiologyExercise TestingPulmonary Function TestingPulmonologyCardiopulmonary Exercise TestingExercise Pulmonary Function TestingGas Exchange AssessmentPulmonary HypertensionCardiopulmonary Exercise Testing InterpretationExercise Gas Exchange TestingGas Exchange During ExerciseHemodynamic PathophysiologyHemodynamic Response To ExerciseIdiopathic Pulmonary HypertensionRespiratory Gas Exchange
BACKGROUND: Decline in oxygen uptake efficiency (OUE), especially during exercise, is found in patients with chronic heart failure. In this study we aimed to test the validity and usefulness of OUE in evaluating gas exchange abnormality of patients with idiopathic pulmonary arterial hypertension (IPAH). METHODS: We retrospectively investigated the cardiopulmonary exercise test (CPET) with gas exchange measurements in 32 patients with confirmed IPAH. All patients also had resting hemodynamic measurements and pulmonary function test (PFT). Sixteen healthy subjects, matched by age, sex, and body size were used as controls, also had CPET and PFT measurements. RESULTS: In IPAH patients, the magnitude of absolute and percentage of predicted (%pred) oxygen uptake efficiency slope (OUES) and oxygen uptake efficiency plateau (OUEP), as well as several other CPET parameters, were strikingly worse than healthy subjects (P<0.0001). Pattern of changes in OUE in patients is similar to that in controls, In IPAH patients, OUE values at rest, warming up, anaerobic threshold and peak exercise were all significantly lower than in normal (P<0.0001). OUEP%pred, better than OUES%pred, correlated significantly with New York Heart Association (NYHA) functional Class (r = -0.724, P<0.005), Total Pulmonary Vascular Resistance (TPVR) (r = -0.694, P<0.005), diffusing capacity for carbon monoxide (DLCO) (r = 0.577, P<0.05), and the lowest ventilation versus CO2 output ratio during exercise (LowestV˙E/V˙CO2) (r = -0.902, P<0.0001). In addition, the coefficient of variation (COV) of OUEP was lower (20.9%) markedly than OUES (34.3%) (P<0.0001). CONCLUSIONS: In patients with IPAH, OUES and OUEP are both significantly lower than the healthy subjects. OUEP is a better physiological parameter than OUES in evaluating the gas exchange abnormality of patients with IPAH.
28
Principles of Exercise Testing and Interpretation.
Annals of Internal Medicine · 1987 · 2.4K citations
Primary Pulmonary Hypertension
Stuart Rich · Annals of Internal Medicine · 1987 · 2.1K citations
Standardization of the measurement of transfer factor (diffusing capacity)
J. E. Cotes, D. J. Chinn, PH Quanjer et al. · European Respiratory Journal · 1993 · 680 citations · Full text
Exercise Pathophysiology in Patients With Primary Pulmonary Hypertension
Xing‐Guo Sun, James E. Hansen, Ronald J. Oudiz et al. · Circulation · 2001 · 620 citations
Medicine, Cardiology, Physiology +17