Spin polarization of gold films via transported (invited)

Mark Johnson

Journal of Applied Physics · 1994 · 66 citations · 12 references

Concepts

Abstract

The spin injection technique has been adapted to a thin-film geometry. Measurements of the spin-coupled voltage Vs as a function of film thickness d result in a determination of the spin diffusion length δs =√DT1 with D the electron diffusion constant, in polycrystalline gold films. The conduction electron spin relaxation time T1 is found to be 4.6±2.5×10−11 s, for the temperature range 4 K<T<70 K. The magnitude of Vs is large enough to suggest device applications. In a three-terminal trilayer device, an electric current Ie biasing a thin permalloy film injects spin-polarized electrons into gold films of thickness 100 nm≤d≤5.1 μm, and induces a nonequilibrium magnetization M̃. A second permalloy film detects the bipolar, spin-coupled voltage eVs=βM̃/χ, where β is the Bohr magneton, χ the Pauli susceptibility and e the electron charge. The sign of Vs depends on the relative orientation of the magnetizations of the permalloy films. In the thin limit, d<δs, the magnitude of the spin-coupled impedance Zs=Vs/Ie scales inversely with d. In the thick limit, d≳δs, Zs is exponentially diminished.

References

12