Journal of Histotechnology · 2013 · 31 citations · 6 references
MedicineNeurosurgerySurgeryMicrosurgerySpinal BiomechanicsSpine SurgeryRodent SurgerySpinal AnatomySpinal Cord AnatomySpinal Cord InjurySpinal Cord PathologyHistological SectioningSpinal Cord HistologyTissue Decalcification
For researchers seeking to collect spinal cord samples from mice and rats while avoiding acid decalcification, few options are available. Laminectomy is the standard method which yields high quality samples, yet is time consuming and technically difficult. Ejection of the cord from the vertebral column is another technique commonly used; however, the literature suggests that this method can damage the spinal tissues and is typically avoided when histology of samples is the desired endpoint. Here, we describe an optimized method for ejection of spinal cords from rats and mice, and compare histological quality of these samples with those collected via laminectomy. Our results show that ejection can yield high quality spinal cord samples and may be suitable for use as an alternative to laminectomy.
6
Guide for the care and use of laboratory animals
Choice Reviews Online · 1997 · 2.9K citations
A Rapid Method for Removal of the Spinal Cord
Andrew Meikle, A. H. Martin · Stain Technology · 1981 · 39 citations
A method for removing the brain and spinal cord as one unit from adult mice and rats
Heather S Kennedy, Floresita Puth, Marjie Van Hoy et al. · Lab Animal · 2011 · 18 citations
Simple method for rapid removal of rat spinal cord
Tony L. Yaksh, Gail J. Harty · Brain Research Bulletin · 1981 · 18 citations
Medicine, Neurobiology, Surgery +6