TFTR vertical x-ray imaging system

L. C. Johnson, M. Bitter, R. Chouinard, S. von Goeler, K.W. Hill, S. L. Liew, K. McGuire, V.K. Paré, N. Sauthoff, K. M. Young

Review of Scientific Instruments · 1986 · 17 citations · 1 references

Concepts

Abstract

A vertically viewing x-ray imaging system (XIS) has been designed to complement the existing 64-channel horizontal system on the tokamak fusion test reactor (TFTR) and enhance measurements of soft x-ray emissivity, plasma (major) radial position, and magnetohydrodynamic (MHD) phenomena. System parameters have been selected to provide adequate signal strength and spatial resolution while permitting a substantial size and cost reduction with respect to the horizontal system. The compact, helium filled x-ray camera employs four eight-channel silicon detector modules and views the plasma through a 3-mil-thick beryllium window, providing 6-cm position resolution at the center. An x-ray absorber foil changer permits energy selection to match the horizontal XIS. Lead and hydrogenous shielding reduce noise from thermonuclear neutrons and associated gamma rays.

References

1