Knee Surgery Sports Traumatology Arthroscopy · 2001 · 37 citations · 7 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryJoint Replacement SurgeryOrthopedic BiomaterialsOrthopedicsComplications Of ArthroplastyDislocation ManagementDislocation MechanicsKnee ArthroplastyRevision ArthroplastyRevision Joint ReplacementPolyethylenePolyethylene ImplantsPolyethylene Insert DesignProsthetic Joint DislocationRevision Knee ArthroplastyTibial Component DesignTotal Knee Arthroplasty Bearings
We report a case of dislocation of the polyethylene inlay in revision total knee arthroplasty. Eight days after revision arthroplasty due to a previous infection, the polyethylene inlay of a PCL- retaining cemented total knee arthroplasty dislocated at about 80 degrees of flexion on the CPM machine. Lateral X-ray examination revealed an anterior slope of the tibial cut of 5 degrees. Correction of the tibial slope to a posterior tibial slope of 7 degrees reduced the forces on the posterior aspect of the inlay and no redislocation occurred. The mechanisms causing tibial inlays to dislocate in TKA are analyzed and discussed.
7