Brazilian Archives of Biology and Technology · 2010 · 41 citations · 27 references
EngineeringEnvironmental EngineeringMicrobiologyElectrochemical EngineeringElectrochemistryWater TreatmentElectrochemical CellsElectrochemical KineticsElectrochemical ReactorsElectrochemical TreatmentElectrolysis ProcessesEnvironmental DisinfectionContact Time EffectsCurrent DensityDisinfectionElectrolysis ReactorsElectrolyzed Water TreatmentEscherichia ColiPower ConsumptionWater Electrolysis
The aim of this work was to investigate the disinfectant effect of electrolysis on chlorine-free water, artificially contaminated with Escherichia coli (CCT-1457) and to evaluate the bactericidal activity of electrolysis and kinetic behavior of a single-cell reactor, with a DSA (Dimensionally Stable Anode) electrode to develop a scaled-up system. A high-density E. coli suspension (10(6) CFU mL-1) was electrolyzed in this reactor at 25, 50 and 75 mA cm-2 for up to 60 min, at flow rates of 200 and 500 L h-1. Bacterial survival fell by 98.9% without addition of chlorinated compounds and a power consumption rate not more than 5.60 kWh m-3 at flow rate of 200 L h-1 and 75 mA cm-2. The process produced a germicidal effect that reached this inactivation rate within a relatively short contact time. Also, a solution of electrolyzed 0.08 M Na2SO4 added to the inoculum showed residual bactericidal effect. The efficiency of disinfection was regulated by both the contact time and current density applied, and a kinetic function for the survival rate was developed for the purpose of scaling up.
27
Hansheng Diao, X.Y Li, J Gu et al. · Process Biochemistry · 2003 · 206 citations
Engineering, Environmental Engineering, Environmental Sciences +17