Optics Letters · 2009 · 40 citations · 14 references
EngineeringBiomedical EngineeringBiomedical OpticsDigital ImagingOcular ImagingForm MeasurementFourier OpticsHolographyThree-dimensional ReconstructionAveraging ConceptsFrequency Domain ProcessingLow-pass FilteringLow-pass FiltersThree-dimensional MeasurementThree-dimensional Shape MeasurementWave Shape MeasurementWavefront Reconstruction
A wavefront reconstruction and three-dimensional (3-D) shape measurement method by a two-step phase-shifting algorithm with arbitrary phase shift in (0,pi) is proposed. In this method, only two phase-shifted intensities, with the removal of the dc term by an averaging technique in spatial domain or low-pass filter operation in the frequency domain, are needed, and the other additional measurements are no longer required. The simulation for an irregular wavefront has shown the feasibility, and the optical experiment for a 3-D face mask in the case of a sinusoidal fringe projection system has illustrated the validity of the proposed method.
14
Phase-shifting digital holography
Ichirou Yamaguchi, Tong Zhang · Optics Letters · 1997 · 2.1K citations
Natural Sciences, Physics, Optics +12
Two-step phase-shifting interferometry and its application in image encryption
Lutong Cai, Xiaoqing Xu, Xin Yang et al. · Optics Letters · 2006 · 347 citations
Shape measurement of small objects using LCD fringe projection with phase shifting
Chenggen Quan, Xin He, Cundeng Wang et al. · Optics Communications · 2001 · 127 citations
Engineering, Mathematics, Metrology +13