IEEE Transactions on Biomedical Engineering · 1988 · 135 citations · 8 references
ComputingBiomedical EngineeringComputational ElectromagneticsMedical PhysicsMicrowave EngineeringAbsorption In TissueAbsorption ModelingAntenna SimulationFinite Difference Time Domain AnalysisMethod Of MomentsMoment AnalysisFinite Difference Time Domain For Microwave CircuitsFinite Difference Time Domain ModelingFinite Difference Time Domain SimulationHuman Body ModelsHuman Body Radiation AbsorptionMethod Of Moments AnalysisMicrowave Attenuation ModelsTime-domain Method Of Moments
The finite-difference time-domain method is used to calculate the specific absorption rate (SAR) within the human body. SAR distributions are calculated using incident frequencies of 100 MHz and 350 MHz for three different cases: (1) a homogeneous man model in free space; (2) an inhomogeneous man model in free space; and (3) an inhomogeneous man model standing on a ground plane. These various cases are used to evaluate the advantage of inhomogeneous models over homogeneous models, and grounded models versus free space models. Comparison is made between the results obtained here and those obtained using the method of moments.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">></ETX>
8