Implant Dentistry · 2014 · 24 citations · 36 references
DentistryImplant DentistryPeriodontologyBone AugmentationBone GraftingDental MaterialsBone Quality AssessmentSurface Modification Of ImplantsBiocompatibility Of Dental ImplantsBone Surface ModificationsBone-implant Contact AssessmentBone-to-implant ContactDental ImplantsImplant-bone InteractionZirconiaZirconia Implants
INTRODUCTION: New biomaterials and their various surface modifications should undergo in vitro and in vivo evaluation before clinical trials. The objective of our in vivo study was to evaluate the biocompatibility of newly created zirconium implant surfaces after implantation in the lower jaw of pigs and compare the osseointegration of these dental implants with commercially available zirconium and titanium implants. MATERIALS AND METHODS: After a healing period of 12 weeks, a histological analysis of the soft and hard tissues and a histomorphometric analysis of the bone-implant contact (BIC) were performed. RESULTS: The implant surfaces showed an intimate connection to the adjacent bone for all tested implants. The 3 newly created zirconium implant surfaces achieved a BIC of 45% on average in comparison with a BIC of 56% from the reference zirconium implants and 35% from titanium implants. Furthermore, the new zirconium implants had a better attachment to gingival and bone tissues in the range of implant necks as compared with the reference implants. CONCLUSION: The results suggest that the new implants comparably osseointegrate within the healing period, and they have a good in vivo biocompatibility.
36
Enhanced Bone Apposition to a Chemically Modified SLA Titanium Surface
Daniel Buser, Nina Broggini, Marco Wieland et al. · Journal of Dental Research · 2004 · 1.2K citations