Journal of Burn Care & Rehabilitation · 1994 · 15 citations · 0 references
MedicineRadiologyImage InterpretationPediatric RadiologyRadiographic AnatomyAirway ObstructionChest RadiographyEndotracheal IntubationPediatric Airway DisordersEndotracheal Tube CareEndotracheal Tube ManagementEndotracheal Tube Position AssessmentManipulationPediatric Chest RadiographyPediatric IntubationRespiratory Gas Exchange
Complications related to endotracheal tubes are frequent in small children and infants. We report a case of a burned 12-month-old child in whom frequent manipulation of the endotracheal tube was required because of recurrent atelectasis and changing position of the endotracheal tube on chest x-ray film. It was then determined that because of variations in head and neck position while chest x-ray films were obtained, the endotracheal tip changed position in the trachea greater than 2.7 cm (greater than 1 inch), although endotracheal tube position was maintained at the level of the teeth. Airway care and gas exchange were subsequently improved by ensuring that patient care and chest x-ray films were performed with the head and neck in similar (neck slightly flexed, head neutral) position.