Dominance improvement by pseudodecoupling

M.P. Ford, K.C. Daly

Proceedings of the Institution of Electrical Engineers · 1979 · 33 citations · 6 references

Concepts

Abstract

Pseudodecoupling enables the design of frequency-dependent precompensators (postcompensators) to improve the column (row) dominance of the compensated plant over an extended range of frequencies. This allows diagonal dominance to be achieved for a wider range of plants than was previously possible. The procedure arises from generalising Hawkins's pseudodiagonalisation procedure in a number of directions; in particular, stability of the compensator is guaranteed. Log σ plots are introduced as a means of determining the degree of dominance over a wide frequency range.

References

6