LUNG MECHANICS IN THE TIMP3 NULL MOUSE AND ITS RESPONSE TO MECHANICAL VENTILATION

Erica L. Martin, Emily Truscott, Timothy C. Bailey, Kevin J. Leco, Lynda A. McCaig, James F. Lewis, Ruud A. W. Veldhuizen

Experimental Lung Research · 2007 · 18 citations · 35 references

Concepts

Abstract

Tissue inhibitor of metalloproteinase-3 (TIMP3) null mice develop emphysema-like airspace enlargement due to an enzymatic imbalance. This study investigates how these abnormalities alter lung mechanics and the response to 2 different mechanical ventilation strategies. Phenotypically, TIMP3 null mice had increased compliance, and decreased resistance, tissue damping, and tissue elastance over wild-type controls. Decreased compliance and increased resistance were observed following the injurious ventilation strategy; however, the TIMP3 null response to both ventilation strategies was similar to wild-type mice. In conclusion, TIMP3 null mice have significant alterations in lung mechanics; however, this does not affect their response to ventilation.

References

35