Cancer · 2006 · 171 citations · 55 references
MedicinePathologyCytopathologyDiagnostic PathologySurgical PathologyBiliary Tract DiseaseCytologic ReportingCytologic ScreeningHepatobiliary PathologyPancreatic CytologyPancreatic PathologyBile Duct CytologyClinical Follow-up ReportingCytologic Specimen AdequacyCytologic Specimen PreparationDirect Smear ExaminationPreoperative Diagnosis
BACKGROUND Duct brushing cytology is an important tool in evaluation of the extrahepatic biliary tract and large pancreatic ducts. The emergence of neoadjuvant therapies underscores the importance of accurate preoperative diagnosis by noninvasive means. Liquid-based preparation methods, such as ThinPrep, have become popular for nongynecologic cytology specimens. METHODS Findings from bile and pancreatic duct brushings were reviewed over the 10-year period of 1994-2003. Cytologic material, imaging reports, and clinical data were reviewed and pathologic and clinical follow-up data were obtained. The slides were prepared by direct smear only (18.8%), direct smear plus cytospin (14.4%), or direct smear plus ThinPrep (66.8%). RESULTS A total of 1118 specimens were identified (1008 bile duct, 110 pancreatic duct) from 864 patients. The cytologic findings were: 53.5% negative, 16.5% malignant, 18.2% suspicious for malignancy, 11% atypical/inconclusive, 0.8% inadequate. Follow-up in the form of either histology or at least 6 months clinical observation was available for 82.2% of cases (n = 971). Overall operating characteristics were: 52.6% sensitivity, 99.4% specificity, 98.9% positive predictive value, 67.1% negative predictive value, and 75.7% accuracy. Diagnostic agreement between cytology and follow-up was the main variable analyzed. Agreement was significantly affected by characteristics of the sampled lesion, with ductal narrowing having the lowest rate of malignancy. In addition, the ThinPrep method showed superior sensitivity and accuracy compared with other preparation methods (P = .02). Nonsignificant associations were noted for patient age and gender, site of lesion, and the presence of either stones or prior stent. CONCLUSION In a large dataset from a single institution, brushing cytology showed modest sensitivity and high specificity. Diagnostic agreement was considerably better for benign cases. The combination of direct smear and the ThinPrep method showed superior sensitivity and accuracy. Cancer (Cancer Cytopathol) 2006. © 2006 American Cancer Society.
55
Triple-tissue sampling at ERCP in malignant biliary obstruction
Jeegar Jailwala, Evan L. Fogel, Stuart Sherman et al. · Gastrointestinal Endoscopy · 2000 · 339 citations
A prospective evaluation of cytology from biliary strictures.
Jennifer Mansfield, S M Griffin, V. Wadehra et al. · Gut · 1997 · 236 citations · Full text