Netherlands Heart Journal · 2012 · 35 citations · 33 references
MedicineCardiologyBioinstrumentationHealth Technology AssessmentTelehealth InformaticsCardiovascular MonitoringPatient MonitoringRemote Follow-up CareRemote MonitoringTelemedicineAlertsCardiac Implantable DevicesCardiac Monitoring SystemsFollow-up Care Via TelehealthImplantable Cardioverter DefibrillatorsPatient Satisfaction EvaluationRemote Cardiac MonitoringRemote Patient Monitoring
Remote monitoring of cardiac implanted electronic devices (CIED: pacemaker, cardiac resynchronisation therapy device and implantable cardioverter defibrillator) has been developed for technical control and follow-up using transtelephonic data transmission. In addition, automatic or patient-triggered alerts are sent to the cardiologist or allied professional who can respond if necessary with various interventions. The advantage of remote monitoring appears obvious in impending CIED failures and suspected symptoms but is less likely in routine follow-up of CIED. For this follow-up the indications, quality of care, cost-effectiveneness and patient satisfaction have to be determined before remote CIED monitoring can be applied in daily practice. Nevertheless remote CIED monitoring is expanding rapidly in the Netherlands without professional agreements about methodology, responsibilities of all the parties involved and that of the device patient, and reimbursement. The purpose of this consensus document on remote CIED monitoring and follow-up is to lay the base for a nationwide, uniform implementation in the Netherlands. This report describes the technical communication, current indications, benefits and limitations of remote CIED monitoring and follow-up, the role of the patient and device manufacturer, and costs and reimbursement. The view of cardiology experts and of other disciplines in conjunction with literature was incorporated in a preliminary series of recommendations. In addition, an overview of the questions related to remote CIED monitoring that need to be answered is given. This consensus document can be used for future guidelines for the Dutch profession.
33
Panos Vardas, Angelo Auricchio, Jean Jacques Blanc et al. · European Heart Journal · 2007 · 902 citations · Full text
[Guidelines for cardiac pacing and cardiac resynchronization therapy].
Panos Vardas, Angelo Auricchio, Jean‐Jacques Blanc et al. · PubMed · 2008 · 551 citations
Long-Term Outcome After ICD and CRT Implantation and Influence of Remote Device Follow-Up
Leslie A. Saxon, David L. Hayes, F. Roosevelt Gilliam et al. · Circulation · 2010 · 518 citations · Full text
Pacemaker and ICD Generator Malfunctions
William H. Maisel, Megan Moynahan, Bram D. Zuckerman et al. · JAMA · 2006 · 352 citations