Cornea · 2009 · 48 citations · 19 references
EngineeringCell BiologyOphthalmologyBiocompatibilityCell TherapyTissue EngineeringAnimal Cell CultureCorneal Tissue EngineeringBoston KeratoprosthesisCell Death AssaysCorneal Epithelial Cell CultureCorneal Epithelial ProliferationCorneal Epithelium ToxicityCytotoxicity AssaysHuman Cell-based In Vitro ModelsViable Cell Count
PURPOSE: To determine in vitro whether titanium is superior in corneal cell compatibility to standard polymethyl-methacrylate (PMMA) for the Boston Keratoprosthesis (KPro). METHODS: Human corneal-limbal epithelial (HCLE) cells were cultured 24, 48, 72, 96, 120, 144, or 168 hours in culture plates alone (controls) or with PMMA or titanium discs. Experiments were performed in triplicate and repeated (final n = 6). To determine if a soluble, toxic factor is emitted from materials, concurrent experiments at 48 and 144 hours were performed with discs placed in Transwell Supports, with HCLE cells plated beneath. As an additional test for soluble factors, cells were incubated 24 hours with disc-conditioned media, and number of viable cells per well was quantified at each timepoint by proliferation assay. To determine if delayed cell proliferation was attributable to cell death, HCLE cell death was measured under all conditions and quantified at each timepoint by cytotoxicity assay. The effects of material on HCLE cell proliferation over time was determined by repeated measures ANOVA. P < 0.05 was statistically significant. RESULTS: HCLE cell proliferation was greater in wells with titanium discs compared to PMMA. Differences between the test discs and control non-disc cocultures were statistically significant over time for both cell proliferation (P = 0.001) and death (P = 0.0025). No significant difference was found using Transwells (P = 0.9836) or disc-conditioned media (P = 0.36). CONCLUSION: This in vitro HCLE cell model demonstrates significantly increased cell proliferation and decreased cell death with cell/titanium contact compared to cell/PMMA contact. Moreover, differences are unlikely attributable to a soluble factor. Prospective in vivo analysis of the two KPro biomaterials is indicated.
19
The profile of repeated corneal transplantation
Valery Bersudsky, Tami Blum-Hareuveni, Uri Rehany et al. · Ophthalmology · 2001 · 142 citations
Medicine, Ophthalmology, Surgery +12
Importance of Nutrition to Corneal Grafts When Used as a Carrier of the Boston Keratoprosthesis
Mona Harissi‐Dagher, Bilal Khan, Debra A. Schaumberg et al. · Cornea · 2007 · 124 citations
Medicine, Ophthalmology, Surgery +12
Introduction to the use of the Boston keratoprosthesis
Claes H. Dohlman, Mona Harissi‐Dagher, Bilal Khan et al. · Expert Review of Ophthalmology · 2006 · 98 citations
Medicine, Ophthalmology, Surgery +13