A new method of determination of trapping parameters of glow peaks relevant to dosimetry and dating from their lifetime

L. Lovedy Singh, R. K. Gartia

Radiation effects and defects in solids · 2011 · 28 citations · 1 references

Concepts

Abstract

In this paper, following a suitable algorithm (brute force), we have extracted the trapping parameters, namely activation energy (E) and frequency factor (s), that play a critical role in determining the stability of a thermoluminescence (TL) peak. As a first step towards this goal, we have derived an expression for τ for non-first-order kinetics (1≤b<2). Using an appropriate algorithm and taking τ (mean lifetime), T m (peak temperature), T (storage temperature) and β (heating rate) as the input parameters, we have retrived E, s and b as the output parameters. The new technique has been tested by considering both dosimetric as well as dating TL peaks. Finally, the reliability of the parameters in terms of consistency is discussed by comparison with data reported in the literature.

References

1