Journal of Surfactants and Detergents · 2012 · 11 citations · 22 references
Natural SciencesChemical EngineeringChemistryCorrosion ScienceSurface ChemistrySurface ScienceCorrosion InhibitorsCorrosion MechanismsCorrosion Of SteelsCorrosion ProtectionCorrosion-resistant MaterialsElectrochemical CorrosionAcid CorrosionCathodic InhibitorsCorrosion InhibitionCorrosion Inhibition MechanismsCorrosion Inhibitors For Mild SteelElectrochemical MeasurementsMixed-type InhibitorsPotentiodynamic Polarization
Abstract 2‐[( E )‐{(1 S ,2 R )‐1‐hydroxy‐1‐phenylpropan‐2‐ylimino}methyl]phenol has been synthesized and its influence on corrosion of mild steel in 1 M HCl solution has been studied by means of weight loss and electrochemical measurements under various circumstances. The inhibitor showed a maximum of 91 % of inhibition efficiency at 100 ppm. Interestingly, the inhibition efficiency has decreased on increasing the inhibitor concentration. This abnormal behavior is attributed to the release of phenolic hydrogen from the molecule. The mechanism of corrosion inhibition follows Langmuir adsorption isotherm. The negative ∆ G ads indicates the spontaneous adsorption of the inhibitor on mild steel surface. Potentiodynamic polarization studies show that it is a mixed type inhibitor with predominant cathodic inhibition. UV–Visible spectroscopy of the inhibitor and inhibitor adsorbed on the mild steel confirmed the chemical interaction of the inhibitor with the metal surface.
22
In vitro and in vivo corrosion measurements of magnesium alloys
Frank Witte, J. Fischer, J. Nellesen et al. · Biomaterials · 2005 · 1.4K citations
Natural Sciences, Materials Engineering, Materials Science +14