Biometrics · 1976 · 342 citations · 5 references
PharmacyBiostatisticsBioequivalenceComparative Effectiveness ResearchGood Clinical PracticeBioequivalence AssessmentBioequivalence Study DesignClinical Equivalence AssessmentClinical TrialsConfidence IntervalsStatistical Analysis Of BioequivalenceConfidence Interval ConstructionConfidence Interval EstimationConfidence Interval EvaluationConfidence Intervals For Differences In MeansTwo-sided Confidence Intervals
The conventional method of setting confidence intervals for the difference of the means of two normal populations gives an interval which is not, in general, symmetrical about zero. A modification of the conventional method which leads to symmetry about zero is discussed and is recommended as particularly appropriate for use in bioequivalence trials. This modification has the effect of decreasing the "effective" length of the confidence interval, on which the decision concerning bioequivalence is based, while increasing the confidence coefficient.
5
Biometrika Tables for Statisticians
I. Richard Savage, E. S. Pearson, Howard Hartley · Mathematics of Computation · 1967 · 1.4K citations
Bioavailability -- A Problem in Equivalence
Carl M. Metzler · Biometrics · 1974 · 638 citations
Biometrika Tables for Statisticians
I. Richard Savage, E. S. Pearson, H. O. Hartley · Mathematics of Computation · 1976 · 563 citations