The Journal of Clinical Pharmacology · 2009 · 21 citations · 30 references
MedicineCardiologyPharmacologyElectrophysiologyPharmacovigilancePreventive CardiologyCardiovascular AssessmentCardiovascular MonitoringElectrocardiogram AnalysisElectrocardiogram InterpretationElectrocardiographySignal EvaluationHeart Rhythm AssessmentPlacebo Effect In TreatmentQt Interval AnalysisQt Interval AssessmentSample Size CalculationSample Size EstimationTangent LinesThorough Qt Study
This study compares the ability of 2 semiautomated methods with a fully automated method for QT measurement to minimize the sample size required to detect a moxifloxacin effect and exclude a placebo effect in a thorough QT/QTc study. The fully automated and 1 of 2 semiautomated methods used a global QT measurement in 12 leads, whereas the other semiautomated method used a tangent method on single lead raw complexes. Mean QTcF intervals were greater when measured on a global QT electrocardiogram than on raw complexes, but the mean magnitudes of DeltaQTcF were similar for all methods. The 3 methods detected a statistically significant increase in QTcF for moxifloxacin compared to placebo and were able to exclude a placebo effect on QTcF in all 62 participants. However, due to a smaller variability, the semiautomated methods allowed these detections with fewer than 20 participants, whereas the fully automated required at least 27 participants.
30
A H BECKETT, M ROWLAND, P TURNER · The Lancet · 1965 · 16.9K citations
The Measurement of the Q-T Interval of the Electrocardiogram
E. Lepeschkin, Borys Surawicz · Circulation · 1952 · 629 citations
Medicine, Cardiology, Physiology +17