Electrophoresis · 2006 · 16 citations · 19 references
Life SciencesBiochemistryPharmaceutical AnalysisBiochemical PharmacologyProtein BiochemistryProtein-protein InteractionsDrug DispositionProtein BindingProtein ElectrophoresisPlasma Protein ElectrophoresisProtein Binding AssessmentReference Sample Analysis
We developed a simple, rapid, and sensitive two-injector microchip electrophoresis frontal analysis (MCE-FA) method for studying drug-plasma protein interactions. In this method, large volumes of a reference sample and drug-plasma protein mixture were simultaneously introduced into the respective sections of the microchannel through the separated injectors and then electrophoresed. Since the reference sample did not meet with the interacting species during migration, it could be used as an external standard. The interaction between heparin and HSA was quantitatively characterized as a model system. The binding constant was found to be (1.53 +/- 0.01) x 10(4) M(-1).
19
Determination of SARS‐coronavirus by a microfluidic chip system
Xiaomian Zhou, Dayu Liu, Runtao Zhong et al. · Electrophoresis · 2004 · 107 citations · Full text