Contact Dermatitis · 2002 · 16 citations · 15 references
Life SciencesDermatologyImmunologyAllergyExperimental PerformanceHypersensitivityPatch TestingSkin Prick TestingAllergen MeasurementEpicutaneous SensitizationPatch Test AllergensPatch Test Readings
Reproducibility of patch test reactions is an important aspect of patch testing. Thin layer rapid use epicutaneous tests (TRUE Test) are preloaded with allergen, whereas Finn Chambers are empty discs that have allergen applied from a syringe. The amount of allergen applied to each Finn Chamber is therefore potentially variable depending on technique. This may increase the risk of non-reproducibility of reactions. We have performed an audit of patch test preparation in our department looking at weight variation of both individual Finn Chambers and 3 completed panels before and after allergen application. We found that the variance in weight was not significant for 2 of the 3 panels and single Finn Chambers with allergen in petrolatum. The variance in weight was significant for single Finn Chambers with allergen in solution and the third panel, which contains an allergen in solution. The clinical significance of these results is unclear.
15
Cobalt allergy in hard metal workers
Torkell. Fischer, Ingela Rystedt · Contact Dermatitis · 1983 · 137 citations
Guidelines for care of contact dermatitis
Jane Bourke, I. H. Coulson, John English · British Journal of Dermatology · 2001 · 123 citations
European multicenter study of the TRUE Test™
J.‐M. Lachapelle, D. P. Bruynzeel, G. Ducombs et al. · Contact Dermatitis · 1988 · 91 citations
Finn chamber patch test technique
Torkel Fischer, Howard I. Maibach · Contact Dermatitis · 1984 · 71 citations