Noninvasive method for retrieval of broken dental implant abutment screw

JagadishReddy Gooty, Sunil Kumar Palakuru, VikramReddy Guntakalla, Mahipal Nera

Contemporary Clinical Dentistry · 2014 · 25 citations · 12 references

DOIFull text

Open access

Concepts

Abstract

Dental implants made of titanium for replacement of missing teeth are widely used because of ease of technical procedure and high success rate, but are not free of complications and may fail. Fracturing of the prosthetic screw continues to be a problem in restorative practice and great challenge to remove the fractured screw conservatively. This case report describes and demonstrates the technique of using an ultrasonic scaler in the removal of the fracture screw fragment as a noninvasive method without damaging the hex of implants.